Certified LED module and controlgear: do they suit the luminaire?

In short

  • An LED module's or a controlgear's certificate shows one thing: the component is according to its own standard, within its own ratings.

  • A luminaire has to show a second thing for each critical component: that the component suits the luminaire it is built into, under the conditions inside it.

  • Component standards set the requirements for components, and end product standards set them for the luminaire, relying on the components being according to their own standards.

  • Suitability is shown by the luminaire's own design and assessment: component ratings matched to its construction, temperatures measured inside it, and its own photometry.

  • Two certified components can still make an unsafe or underperforming luminaire if they don't suit it, so suitability is assessed again whenever a component or the luminaire's rating changes.

 

A new luminaire family is on its way to the market. The LED module came with a safety certificate and performance data. The controlgear came with its own certificate and datasheet. A good part of the luminaire's technical documentation starts from these documents.

They answer one question: is the component according to its own standard? A certificate shows that it has been tested and certified that way, within its own ratings.

The luminaire needs a second question answered: does the component suit the luminaire, under the conditions inside it? In general, no component document can answer that, because the component manufacturer rarely knows which kind of luminaire the component will end up in.

This article follows the two questions through safety and performance, with an example for each.

Component standards and end product standards

A luminaire is an end product built from components, and the most critical of them are the LED module and the controlgear. The end product and the components each have their own standards for safety and performance:

IEC 60598-2-x is the part 2 standard for the luminaire's type, such as IEC 60598-2-1 for fixed general purpose luminaires.
SafetyPerformance
LED luminaireIEC 60598-2-x with IEC 60598-1IEC 62722-2-1
LED controlgearIEC 61347-2-13 with IEC 61347-1IEC 62384
LED moduleIEC 62031IEC 62717

Component standards set the requirements for components, and end product standards for the luminaire. The end product standards rely on the component standards: components are expected to be according to their own standards, and the luminaire's assessment concentrates on whether they suit the conditions in the luminaire.

What component evidence covers

A certificate shows that the component is according to its own standard. A test report shows what has been tested according to the standard, in full or in part. What that evidence covers, within the component's own ratings, doesn't have to be done again for the luminaire.

Where a critical component has no such evidence, the work moves to the luminaire: the component is tested according to the relevant parts of its own standard, as part of the luminaire, which takes time and costs money.

This holds for both safety and performance, and for the LED module the luminaire performance standard says it explicitly. IEC 62722-2-1 calls a luminaire Type A when its LED modules come with evidence of compliance with IEC 62717, and Type B when they don't. It is not the standard's intention to re-measure what the module has already been tested for, so a Type A luminaire can, in general, rest on the module's evidence for values such as colour rendering, colour temperature and lumen maintenance. A Type B luminaire needs more of the testing done on the luminaire itself.

So well-evidenced components save real work in the luminaire's assessment. What they can't show is whether they suit the luminaire.

Safety: does the component suit the luminaire?

If every component in a luminaire is certified, one could expect the luminaire's own assessment to be little more than a stamp on paper. It is an understandable expectation, but it isn't how it works.

With certified components, the luminaire's safety assessment concentrates on suitability. The controlgear is the most safety-critical component, and a few of its ratings decide most of it:

  • Installation type. In a luminaire, the controlgear is usually built-in, with basic or double insulation. The installation type tells what insulation the controlgear's construction provides between its live parts and the parts that may come into contact with the luminaire.

  • Output voltage and the insulation between circuits. The maximum output voltage, together with how the controlgear separates its input and output circuits (non-isolating, separating, isolating or safety isolating), decides the protection needed against contact with live parts on the LED module, and how the module's own insulation has to be dimensioned.

  • tc. Built-in controlgear goes through its thermal tests at an ambient temperature that brings its tc point up to the rated value, at rated input voltage and at the output that gives the highest temperature. Its internal parts, such as transformer windings, optocouplers and bridging capacitors, are then checked against the limits of the standard. Those tests cover the controlgear up to its rated tc value, so in the luminaire the tc point must stay at or below that value.

The LED module has its own tc point, construction and rating, and the same rule applies. The controlgear's output voltage and insulation decide what the module has to withstand. And the module adds one more check: blue light hazard. Under IEC 62471-7:2023, modules and luminaires are placed in blue light hazard application groups, such as BLH-A, BLH-B and BLH-C, and the starting point is that the luminaire doesn't increase the blue light hazard of the module. A BLH-A module can go into a luminaire of any application group; a BLH-B or BLH-C module needs further assessment in a luminaire of a lower group.

All of these ratings are on the components' certificates and datasheets. What those documents can't show is whether the ratings fit the luminaire: its construction, its insulation, the temperatures inside it. That is for the luminaire's own design and assessment to show. An LED module and a controlgear can both be certified, and the luminaire built from them can still be unsafe if they don't suit it.

For example, take an LED module on a metal-core circuit board and a non-isolating built-in (with basic insulation) controlgear, both ENEC certified. Both are according to their own standards.

Now put them in a metal-encased class II luminaire where the live parts of the LED module are accessible in normal use. That construction has several problems, and the result is a luminaire with a serious risk of electric shock, built entirely from certified components.

Performance: do the component's values hold in the luminaire?

In performance, suitability is mostly about temperature. The LED module's rated performance values, such as its lumen maintenance, are stated at a performance temperature tp. The controlgear's lifetime is stated for a given temperature at its tc point, or in some cases at a separate lifetime temperature tl (IEC 62384, Annex B). The hotter the controlgear runs, the shorter its life.

Whether those values hold in the luminaire depends on the temperatures the components actually reach there. In a Type A luminaire, the module's values carry over only after a thermal test in normal operation according to IEC 60598-1, made at tq, the luminaire's rated ambient performance temperature, shows that the module's tp point stays at or below its tp. Beyond that, the luminaire's assessment concentrates on what the luminaire itself affects, such as the light it gives out. The module's rated luminous flux is not the luminaire's.

For example, take an LED module with two lifetime claims from its maker: L80 50 000 h at tp 65 °C, and L80 35 000 h at tp 75 °C. In the luminaire's thermal test at its tq of 25 °C, the module's tp point reaches 72 °C. The 50 000 h claim doesn't hold in this luminaire, because 72 °C is above 65 °C; the 35 000 h claim does, because 72 °C is below 75 °C.

The controlgear works the same way. A datasheet that gives 50 000 h at tc 75 °C and 100 000 h at tc 65 °C supports 50 000 h in a luminaire where its tc point runs at 71 °C.

In both cases the component's evidence stays the same. Which of its lifetime values the luminaire can rest on depends on the temperature measured inside the luminaire.

Some designs bring values back to the luminaire that the module's evidence would otherwise cover. If a luminaire combines different LED modules or adds secondary optics, values such as CRI and CCT may need measuring on the luminaire itself, for example when colours are mixed.

 
 

Where the luminaire's own assessment begins

Component evidence shows whether a component is according to its own standard, and good component evidence saves real work in the luminaire's assessment. It can't show whether the component suits the luminaire. That has to come from the luminaire's own design and assessment, for every critical component, and again whenever a component or the luminaire's rating changes.

Showing that each component suits the luminaire is a large part of the work behind a luminaire's quality. For every luminaire value, the question is the same: based on what? In a Complite review, we examine what each key value is based on: the component's evidence, and what shows that the component suits the luminaire.

Patrik Jokiharju

I’m Patrik, the founder of Complite. I’ve worked with luminaires as a lighting designer, a testing engineer, a technical specialist at a component manufacturer and a lighting product specialist in an accredited third-party testing laboratory. I’m also a member of SK 34 Luminaires and Associated Equipment, SESKO’s national standardisation committee in Finland for the European CLC/TC 34 and the international IEC TC 34.

Next
Next

What a datasheet can't show: the work behind a quality luminaire